You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > Pani Internal Articles > Standard Pani-defined KPIs
Standard Pani-defined KPIs
print icon

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Pressure Drop (Reverse Osmosis) Reverse Osmosis Input Units Input Frequency Feed Pressure. Concentrate Pressure Overview. Analytics, Insights Base Pressure Drop RO pressure drop. Feed pressure minus concentrate pressure Any
Recovery Reverse Osmosis % Input Frequency Feed Flowrate, Permeate Flowrate Overview. Analytics, Insights Base Recovery RO recovery. Ratio of permeate flowrate to feed flowrate. Drop rows where feed flowrate is null or zero. Any
Feed Flowrate Reverse Osmosis Input Units Input Frequency Permeate Flowrate, Concentrate Flowrate Overview. Analytics, Insights Base Feed Flowrate RO feed flowrate. Permeate flowrate plus concentrate flowrate. Any
Permeate Flowrate Reverse Osmosis Input Units Input Frequency Feed Flowrate, Concentrate Flowrate Overview. Analytics, Insights Base Permeate Flowrate RO permeate flowrate. Feed flowrate minus concentrate flowrate. Any
Concentrate Flowrate Reverse Osmosis Input Units Input Frequency Feed Flowrate, Permeate Flowrate Overview. Analytics, Insights Base Concentrate Flowrate RO concentrate flowrate. Feed flowrate minus permeate flowrate. Any
Salt Passage Reverse Osmosis % Input Frequency Permeate TDS, Feed TDS Overview. Analytics, Insights Base Salt Passage RO salt passage. Ratio of permeate TDS to feed TDS. Any
Feed TDS Reverse Osmosis Input Units Input Frequency Feed Conductivity Overview. Analytics, Insights Base Feed TDS Feed total dissolved solids. Converted from conductivity with constant K. Any
Permeate TDS Reverse Osmosis ppm Input Frequency Permeate Conductivity Overview. Analytics, Insights Base Permeate TDS Permeate total dissolved solids. Converted from conductivity with constant K. Any
Concentrate TDS Reverse Osmosis ppm Input Frequency Concentrate Conductivity   Base Concentrate TDS Concentrate total dissolved solids. Converted from conductivity with constant K. Any
Feed TDS (Mass Balance) Reverse Osmosis ppm Input Frequency Feed Flowrate, Concentrate Flowrate, Permeate Flowrate, Concentrate TDS, Permeate TDS Overview. Analytics, Insights Base Feed TDS RO feed TDS. Calculated from flowrates and concentrate/permeate TDS, when feed conductivity is not measured. Any
Concentrate TDS (Mass Balance) Reverse Osmosis ppm Input Frequency Feed Flowrate, Concentrate Flowrate, Permeate Flowrate, Feed TDS, Permeate TDS Overview, Analytics Base Concentrate TDS RO concentrate TDS. Calculated from flowrates and feed/permeate TDS, when concentrate conductivity is not measured. Any
Permeate TDS (Mass Balance) Reverse Osmosis ppm Input Frequency Feed Flowrate, Concentrate Flowrate, Permeate Flowrate, Feed TDS, Concentrate TDS Overview, Analytics, Insights Base Permeate TDS RO permeate TDS. Calculated from flowrates and feed/concentrate TDS, when permeate conductivity is not measured. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Daily Running Hours Reverse Osmosis hours Daily On/Off Analytics Base Daily Running Hours Daily equipment running hours. Integral of base on/off signal. Any
Weekly Running Hours Reverse Osmosis hours Daily Daily Running Hours Analytics Base Weekly Running Hours Weekly equipment running hours. Derived from daily running hours. Any
Weekly Uptime Reverse Osmosis I% Daily On/Off Analytics Base Weekly Uptime Weekly equipment uptime, as a percentage of the last week. Any
Daily Production Reverse Osmosis Derived From Input Units Daily Permeate Flowrate Analytics, Overview Base Daily Production Daily water produced by RO. Integrated permeate flowrate, including off-periods as 0's. Any
Weekly Production Reverse Osmosis Derived From Input Units Daily Daily Production Analytics Base Weekly Production Weekly water produced. Derived from daily production. Any
Pressure Drop (Cartridge Filter) Reverse Osmosis Input Units Input Frequency Inlet Pressure, Outlet Pressure Overview. Analytics, Insights Base Pressure Drop Cartridge filter pressure drop. Inlet pressure minus outlet pressure. Any
Pressure Boost Reverse Osmosis Input Units Input Frequency Inlet Pressure, Outlet Pressure Overview. Analytics Base Pressure Boost Pump pressure boost. Outlet pressure minus inlet pressure. Any
VFD Percentage Reverse Osmosis % Input Frequency Rotational Speed Overview. Analytics Base VFD Percentage Pump variable frequency drive speed, as a percentage of maximum speed. Any
Rotational Speed Reverse Osmosis Input Units Input Frequency VFD Percentage Intermediate Base Rotational Speed Pump rotational speed, calculated from VFD percentage and maximum rotational speed. Any
Daily Water Treated (Reverse Osmosis) Reverse Osmosis Derived From Input Units Daily Feed Flowrate Overview, Analytics Base Daily Water Treated Daily water treated, as integration of feed flowrate. Any
Daily Water Treated Reverse Osmosis Derived From Input Units Daily Inlet Flowrate Analytics, Overview Base Daily Water Treated Daily water treated, as integration of inlet flowrate. Any
Weekly Water Treated Reverse Osmosis Derived From Input Units Daily Daily Water Treated Analytics Base Weekly Water Treated Weekly water treated. Derived from daily water treated Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Number Membranes Replaced Reverse Osmosis - Intermittent   Intermediate Base Number Membranes Replaced Keeps track of membrane replacement events. Indicates each replacement event, with the value equal to the number of membranes inserted. Any
Daily Membranes Replaced Reverse Osmosis - Daily Number Membranes Replaced Overview, Analytics Base Daily Membranes Replaced Daily number of membranes replaced, as the sum of all membrane insertions for children assets each day. Any
Membrane Replacement Signal Reverse Osmosis - Daily Daily Membranes Replaced Overview, Analytics Base Membrane Replacement Signal Signal identifying when a membrane replacement has occurred that day for any children assets. Any
Running Hours Since Last Cleaning Reverse Osmosis hours Input Frequency On/Off, Membrane Cleaning Signal Analytics Base Running Hours Since Last Cleaning The integrated running hours since the last cleaning event (and up to the next). Any
Running Hours Since Last Replacement Reverse Osmosis hours Input Frequency On/Off, Membrane Replacement Signal Analytics Base Running Hours Since Last Replacement The integrated running hours since the last replacement event (and up to the next). Any
Average Running Hours Between Cleanings Reverse Osmosis hours Intermittent Running Hours Since Last Cleaning Analytics Base Average Running Hours Between Cleanings Average running hours between cleanings, of the last 10 cleanings. Any
Time Since Last Cleaning Reverse Osmosis days Daily On/Off, Membrane Cleaning Signal Analytics Base Time Since Last Cleaning The integrated time since the last cleaning event (and up to the next), including off-periods. Any
Time Since Last Replacement Reverse Osmosis days Daily On/Off, Membrane Replacement Signal Analytics Base Time Since Last Replacement The integrated time since the last replacement event (and up to the next), including off-periods. Any
Average Time Between Cleanings Reverse Osmosis hours Intermittent Time Since Last Cleaning Analytics Base Average Time Between Cleanings Average time between cleanings, of the last 10 cleanings. Any
Water Produced Since Last Cleaning Reverse Osmosis Derived From Input Units Input Frequency Membrane Cleaning Signal, Permeate Flowrate Analytics Base Production Since Last Cleaning The integrated permeate flow the last cleaning event (and up to the next). Any
Water Produced Since Last Replacement Reverse Osmosis Derived From Input Units Input Frequency Permeate Flowrate, Membrane Replacement Signal Analytics Base Production Since Last Replacement The integrated permeate flow the last replacement event (and up to the next). Any
Average Water Produced Between Cleanings Reverse Osmosis Derived From Input Units Intermittent Production Since Last Cleaning Analytics Base Average Production Between Cleanings Average water produced between cleanings, of the last 10 cleanings. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Feed Pressure (Reverse Osmosis) Reverse Osmosis Input Units Input Frequency Concentrate Pressure, Pressure Drop Overview. Analytics, Insights Base Feed Pressure RO feed pressure. Pressure drop plus concentrate pressure. Any
Concentrate Pressure (Reverse Osmosis) Reverse Osmosis Input Units Input Frequency Pressure Drop, Feed Pressure Overview. Analytics, Insights Base Concentrate Pressure RO concentrate pressure. Feed pressure minus pressure drop. Any
Power Consumption (DC) Reverse Osmosis kW Input Frequency DC Voltage, DC Current Overview. Analytics Brite Power Consumption Electrical power used by equipment with DC electricity supply. Product of voltage and current, if measured. Any
Power Consumption (1 Phase AC) Reverse Osmosis kW Input Frequency Voltage, Current Overview. Analytics Brite Power Consumption Electrical power used by equipment with single phase AC electricity supply. Product of voltage, current and power factor. Any
Power Consumption (3 Phase AC) Reverse Osmosis kW Input Frequency Line Voltage, Current Overview. Analytics Brite Power Consumption Electrical power used by AC equipment with 3 phase AC electricity supply. Calculated from voltage, current and power factor. Any
Recovery (Pressure Vessels) Reverse Osmosis % Input Frequency Feed TDS, Permeate TDS, Concentrate TDS Overview. Analytics Brite Recovery Recovery for the individual PV using concentrations from profiling. Any
Reference Feed Flowrate Reverse Osmosis Input Units Intermittent Reference Permeate Flowrate, Reference Concentrate Flowrate Intermediate Brite Reference Feed Flowrate Reference feed flowrate. Calculated from reference permeate and concentrate flowrates. Any
Reference Permeate Flowrate Reverse Osmosis Input Units Intermittent Reference Concentrate Flowrate, Reference Feed Flowrate Intermediate Brite Reference Permeate Flowrate Reference permeate flowrate. Calculated from reference feed and concentrate flowrates. Any
Reference Pressure Drop Reverse Osmosis Input Units Intermittent Reference Feed Pressure, Reference Concentrate Pressure Intermediate Brite Reference Pressure Drop Reference pressure drop. Calculated from reference concentrate and feed pressures Any
Reference Concentrate Pressure Reverse Osmosis Input Units Intermittent Reference Feed Pressure, Reference Pressure Drop Intermediate Brite Reference Concentrate Pressure Reference concentrate pressure. Calculated from reference feed pressure and pressure drop. Any
Reference Feed Pressure Reverse Osmosis Input Units Intermittent Reference Concentrate Pressure, Reference Pressure Drop Intermediate Brite Reference Concentrate Pressure Reference feed pressure. Calculated from reference concentrate pressure and pressure drop. Any
Reference Salt Passage Reverse Osmosis % Intermittent Reference Feed TDS, Reference Permeate TDS Intermediate Brite Reference Salt Passage Normalization Factor Reference salt passage. Calculated from reference feed and permeate TDS. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Ion Concentrations Reverse Osmosis mg/L Intermittent PROPREITARY Intermediate Brite PROPREITARY PROPREITARY Any
Net Positive Suction Head Available Reverse Osmosis As Specified Input Frequency Temperature, Inlet Pressure, Inlet TDS, Inlet Density Insights Brite NPSHa Net positive suction head available for a pump. Must be greater than NPSH required. Any
Concentrate Throttling Valve Coefficient Reverse Osmosis As Specified Input Frequency Concentrate Pressure, Concentrate Flowrate, Concentrate Density, Outlet Pressure Insights Brite Concentrate Throttling Valve Coefficient The flow coefficient of the concentrate throttling valve. Approximated assuming the pressure after the valve is approximately atmospheric if the outlet pressure is not known. Any
Membrane Cleaning or Replacement Signal Reverse Osmosis   Intermittent Membrane Cleaning Signal, Membrane Replacement Signal Intermediate Brite Membrane Cleaning or Replacement Signal Signal identifying when a membrane replacement or cleaning has occurred. Any
Normalized Permeate Flow Change Since Last Cleaning Reverse Osmosis % Input Frequency Normalized Permeate Flow, normalized permeate flow after cleaning Analytics Brite Permeate Flow Change Since Last Cleaning Percentage change in normalized permeate flow since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements. Any
Normalized Permeate Flow Change Since Last Replacement Reverse Osmosis % Input Frequency Normalized Permeate Flow, Membrane Replacement Signal Analytics Brite Permeate Flow Change Since Last Replacement Percentage change in normalized permeate flow since last replacement, relative to the value after the last replacement Any
Average Normalized Permeate Flow Change Per Month Since Last Cleaning Reverse Osmosis % Input Frequency Membrane Cleaning or Replacement Signal, Normalized Permeate Flow Change Since Last Cleaning Analytics Brite Permeate Flow Change Per Month Since Last Cleaning Average percentage change per month in normalized permeate flow since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements. Any
Normalized Pressure Drop Change Since Last Cleaning Reverse Osmosis % Input Frequency Normalized Pressure Drop, Membrane Cleaning or Replacement Signal Analytics Brite Pressure Drop Change Since Last Cleaning Percentage change in normalized product flow since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements. Any
Normalized Pressure Drop Change Since Last Replacement Reverse Osmosis % Input Frequency Normalized Pressure Drop, Membrane Replacement Signal Analytics Brite Pressure Drop Change Since Last Replacement Percentage change in normalized pressure drop since last replacement, relative to the value after the last replacement. Any
Average Normalized Pressure Drop Change Per Month Since Last Cleaning Reverse Osmosis % Input Frequency Membrane Cleaning or Replacement Signal, Normalized Pressure Drop Change Since Last Cleaning Analytics Brite Pressure Drop Change Per Month Since Last Cleaning Average percentage change per month in normalized pressure drop since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements. Any
Normalized Salt Passage Change Since Last Cleaning Reverse Osmosis % Input Frequency Normalized Salt Passage, Membrane Cleaning or Replacement Signal Analytics Brite Salt Passage Change Since Last Cleaning Percentage change in normalized salt passage since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements Any
Normalized Salt Passage Change Since Last Replacement Reverse Osmosis % Input Frequency Normalized Salt Passage, Membrane Replacement Signal Analytics Brite Salt Passage Change Since Last Replacement Percentage change in normalized salt passage since last replacement, relative to the value after the last replacement. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Average Normalized Salt Passage Change Per Month Since Last Cleaning Reverse Osmosis % Input Frequency Membrane Cleaning or Replacement Signal, Normalized Salt Passage Change Since Last Cleaning Analytics Brite Salt Passage Change Per Month Since Last Cleaning Average percentage change per month in normalized permeate flow since last cleaning, relative to the value after the last cleaning. Replacements are counted as "cleanings" to avoid unfair comparisons across replacements. Any
Feed Pressure (Pressure Vessels) Reverse Osmosis Input Units Intermittent   Analytics Brite   PROPREITARY Any
Flux Reverse Osmosis As Specified Input Frequency Permeate Flowrate   Brite Flux Feed total dissolved solids. Converted from conductivity assuming seawater properties Seawater
Feed TDS (SWRO) Reverse Osmosis mg/L Input Frequency Feed Conductivity, Feed Temperature Overview. Analytics, Insights Base Feed TDS Feed total dissolved solids. Converted from conductivity assuming seawater properties. Seawater
Permeate TDS (SWRO) Reverse Osmosis mg/L Input Frequency Permeate Conductivity, Permeate Temperature Overview. Analytics, Insights Base Permeate TDS Permeate total dissolved solids. Converted from conductivity assuming seawater properties. Seawater
Concentrate TDS (SWRO) Reverse Osmosis mg/L Input Frequency Concentrate TDS, Concentrate Temperature Overview. Analytics, Insights Base Concentrate TDS Concentrate total dissolved solids. Converted from conductivity assuming seawater properties. Any
Power Consumption (Centrifugal Pump) Reverse Osmosis kW Input Frequency Inlet Flowrate, Rotational Speed Overview. Analytics Brite Power Consumption Electrical power used by a centrifugal pump. Calculated from flow rate, pump speed and a pump power curve. Any
Daily Energy Consumption Reverse Osmosis As Specified Daily Power Consumption Overview. Analytics Brite Daily Energy Consumption Daily energy consumption by integrating power. Any
Weekly Energy Consumption Reverse Osmosis As Specified Daily Daily Energy Consumption Analytics Brite Weekly Energy Consumption Weekly energy consumption. Derived from daily energy consumption. Any
Specific Energy Consumption (Reverse Osmosis) Reverse Osmosis As Specified Input Frequency Power Consumption, Permeate Flowrate Analytics, Overview Brite Specific  Energy Consumption Specific energy consumption, as power consumption divided by permeate flow. Any
Efficiency Reverse Osmosis % Input Frequency Feed Flowrate, Pressure Boost, Power Consumption Analytics, Overview Brite Efficiency Pump efficiency, as ratio of fluid power to electrical power required to run the pump. Any
Feed Osmotic Pressure (SWRO) Reverse Osmosis bar Input Frequency Feed Pressure, Feed TDS, Temperature Intermediate Brite Feed Osmotic Pressure Osmotic pressure of the feed stream. Calculated assuming the composition is that of standard seawater. Seawater

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Permeate Osmotic Pressure (SWRO) Reverse Osmosis bar Input Frequency Permeate TDS, Permeate Pressure, Temperature Intermediate Brite Permeate Osmotic Pressure Osmotic pressure of the permeate stream. Calculated assuming the composition is that of standard seawater. Seawater
Concentrate Osmotic Pressure (SWRO) Reverse Osmosis bar Input Frequency Concentrate Pressure, Concentrate TDS, Temperature Intermediate Brite Concentrate Osmotic Pressure Osmotic pressure of the concentrate stream. Calculated assuming the composition is that of standard seawater. Seawater
Reference Feed Osmotic Pressure (SWRO) Reverse Osmosis bar Intermittent Reference Feed TDS, Reference Feed Pressure, Reference Temperature Intermediate Brite Reference Feed Osmotic Pressure Reference osmotic pressure of the feed stream. Calculated assuming the composition is that of standard seawater. Seawater
Reference Permeate Osmotic Pressure (SWRO) Reverse Osmosis bar Intermittent Reference Permeate TDS, Reference Permeate Pressure, Reference Temperature Intermediate Brite Reference Permeate Osmotic Pressure Reference osmotic pressure of the permeate stream. Calculated assuming the composition is that of standard seawater. Seawater
Reference Concentrate Osmotic Pressure (SWRO) Reverse Osmosis bar Intermittent Reference Concentrate TDS, Reference Concentrate Pressure, Reference Temperature Intermediate Brite Reference Concentrate Osmotic Pressure Reference osmotic pressure of the concentrate stream. Calculated assuming the composition is that of standard seawater. Seawater
Inlet Density (SWRO) Reverse Osmosis kg/m3 Input Frequency Inlet TDS, Inlet Temperature, Inlet Pressure Intermediate Brite Inlet Density Density of the inlet stream. Calculated assuming the composition is that of standard seawater. Seawater
Concentrate Density (SWRO) Reverse Osmosis kg/m3 Input Frequency Concentrate TDS, Concentrate Temperature, Concentrate Pressure Intermediate Brite Concentrate Density Density of the concentrate stream. Calculated assuming the composition is that of standard seawater. Seawater
Permeate Flow Normalization Factor Reverse Osmosis Input Units Input Frequency Pressure Drop, Feed Pressure, Feed Osmotic Pressure, Permeate Osmotic Pressure, Concentrate Osmotic Pressure, Temperature, Permeate Pressure Intermediate Brite Permeate Flow Normalization Factor Factor for calculating normalized permeate flow. Any
Pressure Drop Normalization Factor Reverse Osmosis Input Units Input Frequency Feed Flowrate, Permeate Flowrate Intermediate Brite Pressure Drop Normalization Factor Factor for calculating normalized pressure drop. Any
Salt Passage Normalization Factor Reverse Osmosis % Input Frequency Feed Flowrate, Permeate Flowrate, Temperature Intermediate Brite Salt Passage Normalization Factor Factor for calculating normalized salt passage. Any
Reference Permeate Flow Normalization Factor Reverse Osmosis - Input Frequency Permeate Flowrate, Reference Pressure Drop Normalization Factor, Reference Feed Pressure, Reference Temperature, Reference Permeate Pressure, Reference Feed Osmotic Pressure, Reference Permeate Osmotic Pressure, Reference Concentrate Osmotic Pressure Intermediate Brite Reference Permeate Flow Normalization Factor Reference factor for calculating normalized permeate flow. Any
Reference Pressure Drop Normalization Factor Reverse Osmosis - Input Frequency Pressure Drop, Reference Feed Flowrate, Reference Permeate Flowrate Intermediate Brite Reference Pressure Drop Normalization Factor Reference factor for calculating normalized pressure drop. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Reference Salt Passage Normalization Factor Reverse Osmosis - Input Frequency Salt Passage, Reference Temperature, Reference Feed Flowrate, Reference Permeate Flowrate Intermediate Brite Reference Salt Passage Normalization Factor Reference factor for calculating normalized salt passage. Any
Normalized Permeate Flowrate Reverse Osmosis Input Units Input Frequency Permeate Flowrate, Flow Normalization Factor, Reference Flow Normalization Factor Overview, Analytics Brite Normalized Permeate Flow Permeate flowrate normalized to reference conditions. Any
Normalized Pressure Drop Reverse Osmosis Input Units Input Frequency Pressure Drop, Pressure Drop Normalization Factor, Reference Pressure Drop Normalization Factor Overview, Analytics Brite Normalized Pressure Drop Pressure drop normalized to reference conditions Any
Normalized Salt Passage Reverse Osmosis % Input Frequency Salt Passage, Salt Passage Normalization Factor, Reference Salt Passage Normalization Factor

Overview, Analytics

Brite Normalized Salt Passage Salt passage normalized to reference conditions Any
Net Positive Suction Head Required Reverse Osmosis As Specified Input Frequency Inlet Flowrate, Rotational Speed Insights Brite NPSHr Net positive suction head required for a pump. Must be less than NPSH available Any
Normalized Permeate Flow Before Cleaning Reverse Osmosis Input Units Intermittent Normalized Permeate Flow, Membrane Cleaning Signal Intermediate Brite Normalized Permeate Flow Before Cleaning Representative value of normalized permeate flow before cleaning. Used for determining effectiveness of cleanings. Any
Normalized Permeate Flow After Cleaning Reverse Osmosis Input Units Intermittent Normalized Permeate Flow, Membrane Cleaning Signal Intermediate Brite Normalized Permeate Flow After Cleaning Representative value of normalized permeate flow after cleaning. Used for determining effectiveness of cleanings and membrane health. Any
Normalized Pressure Drop Before Cleaning Reverse Osmosis Input Units Intermittent Normalized Pressure Drop, Membrane Cleaning Signal Intermediate Brite Normalized Pressure Drop Before Cleaning Representative value of normalized pressure drop before cleaning. Used for determining effectiveness of cleanings. Any
Normalized Pressure Drop After Cleaning Reverse Osmosis Input Units Intermittent Normalized Pressure Drop, Membrane Cleaning Signal Intermediate Brite Normalized Pressure Drop After Cleaning Representative value of normalized pressure drop after cleaning. Used for determining effectiveness of cleanings and membrane health. Any
Normalized Salt Passage Before Cleaning Reverse Osmosis Input Units Intermittent Normalized Salt Passage, Membrane Cleaning Signal Intermediate Brite Normalized Salt Passage Before Cleaning Representative value of normalized salt passage before cleaning. Used for determining effectiveness of cleanings. Any
Normalized Salt Passage After Cleaning Reverse Osmosis Input Units Intermittent Normalized Salt Passage, Membrane Cleaning Signal

Intermediate

Brite Normalized Salt Passage After Cleaning Representative value of normalized salt passage after cleaning. Used for determining effectiveness of cleanings and membrane health. Any
New Membrane Permeate Flow Reverse Osmosis Input Units Input Frequency Flow Normalization Factor, Reference Flow Normalization Factor, Reference Permeate Flowrate, Permeate Flowrate Analytics Brite Permeate Flow of New Membrane Expected permeate flow rate with a new membrane, i.e. reverse normalized permeate flow rate. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
New Membrane Pressure Drop Reverse Osmosis Input Units Input Frequency Pressure Drop Normalization Factor, Reference Pressure Drop Normalization Factor, Reference Pressure Drop, Pressure Drop Analytics Brite Pressure Drop of New Membrane Expected pressure drop with a new membrane, i.e. reverse normalized pressure drop Any
New Membrane Salt Passage Reverse Osmosis % Input Frequency Salt Passage Normalization Factor, Reference Salt Passage Normalization Factor, Reference Salt Passage, Salt Passage Analytics Brite Salt Passage of New Membrane Expected salt passage with a new membrane, i.e. reverse normalized salt passage. Any
Feed Osmotic Pressure Reverse Osmosis bar Input Frequency PROPREITARY Intermediate Brite PROPREITARY PROPREITARY Any
Permeate Osmotic Pressure Reverse Osmosis bar Input Frequency PROPREITARY Intermediate Brite PROPREITARY PROPREITARY Any
Concentrate Osmotic Pressure Reverse Osmosis bar Input Frequency PROPREITARY Intermediate Brite PROPREITARY PROPREITARY Any
Reference Feed Osmotic Pressure Reverse Osmosis bar Intermittent Ion Concentrations, Reference Feed TDS, Reference Temperature Intermediate Brite Reference Feed Osmotic Pressure Reference osmotic pressure of the feed stream. Calculated from ion concentrations in water analysis reports. Any
Reference Permeate Osmotic Pressure Reverse Osmosis bar Intermittent Ion Concentrations, Reference Permeate TDS, Reference Temperature Intermediate Brite Reference Permeate Osmotic Pressure Reference osmotic pressure of the permeate stream. Calculated from ion concentrations in water analysis reports. Any
Reference Concentrate Osmotic Pressure Reverse Osmosis bar Intermittent Ion Concentrations, Reference Concentrate TDS, Reference Temperature Intermediate Brite Reference Concentrate Osmotic Pressure Reference osmotic pressure of the concentrate stream. Calculated from ion concentrations in water analysis reports. Any
Inlet Density Reverse Osmosis kg/m3 Input Frequency Inlet TDS, Ion Concentrations Intermediate Brite Inlet Density Density of the inlet stream. Calculated from ion concentrations in water analysis reports. Any
Concentrate Density Reverse Osmosis kg/m3 Input Frequency Concentrate TDS, Ion Concentrations Intermediate Brite Concentrate Density Density of the concentrate stream. Calculated from ion concentrations in water analysis reports Any
Permeate Flow Percent Change Due To Membrane Conditions Reverse Osmosis % Input Frequency Flow Normalization Factor, Reference Flow Normalization Factor, Reference Permeate Flowrate, Permeate Flowrate Analytics Brite Permeate Flow Change Due To Degradation Percent change in permeate flowrate relative to reference due to membrane conditions. Any
Permeate Flow Percent Change Due To Operating Conditions Reverse Osmosis % Input Frequency Flow Normalization Factor, Reference Permeate Flowrate, Reference Flow Normalization Factor Analytics Brite Permeate Flow Change Due To Operation Percent change in permeate flowrate relative to reference due to operating conditions. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Pressure Drop Percent Change Due To Membrane Conditions Reverse Osmosis % Input Frequency Pressure Drop, Pressure Drop Normalization Factor, Reference Pressure Drop Normalization Factor, Reference Pressure Drop Analytics Brite Pressure Drop Change Due to Degradation Percent change in pressure drop relative to reference due to membrane conditions. Any
Pressure Drop Percent Change Due To Operating Conditions Reverse Osmosis % Input Frequency Reference Pressure Drop Normalization Factor, Reference Pressure Drop, Pressure Drop Normalization Factor Analytics Brite Pressure Drop Change Due to Operation Percent change in pressure drop relative to reference due to operating conditions Any
Salt Passage Percent Change Due To Membrane Conditions Reverse Osmosis % Input Frequency Salt Passage, Salt Passage Normalization Factor, Reference Salt Passage Normalization Factor, Reference Salt Passage Analytics Brite Salt Passage Change Due to Degradation Percent change in salt passage relative to reference due to membrane conditions. Any
Salt Passage Percent Change Due To Operating Condition Reverse Osmosis % Input Frequency Salt Passage Normalization Factor, Reference Salt Passage Normalization Factor, Reference Salt Passage Analytics Brite Salt Passage Change Due to Operation Percent change in salt passage relative to reference due to operating conditions. Any
Maximum Membrane Element Flux (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Maximum Membrane Element Recovery (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Maximum Membrane Element Feed Flowrate (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Minimum Membrane Element Concentrate Flowrate (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Maximum Membrane Element Permeate Flowrate (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Membrane Water Permeability (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Membrane Salt Permeability (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Feed Flowrate (From RO Model) Reverse Osmosis         Genius   Feed flowrate calculated by modelling RO operation. Any

 

 

Use the scrollbars at the bottom of the tables:

 

KPI Name Application Output Units Output Frequency Input Properties Power these
Pani features
Lowest
Product
Tier
Output Property Description Target Market
Concentrate Flowrate (From RO Model) Reverse Osmosis         Genius   Concentrate flowrate calculated by modelling RO operation. Seawater
Permeate Flowrate (From RO Model) Reverse Osmosis         Genius   Permeate flowrate calculated by modelling RO operation. Seawater
Feed TDS (From RO Model) Reverse Osmosis         Genius   Feed TDS calculated by modelling RO operation. Seawater
Concentrate TDS (From RO Model) Reverse Osmosis         Genius   Concentrate TDS calculated by modelling RO operation. Seawater
Permeate TDS (From RO Model) Reverse Osmosis         Genius   Permeate TDS calculated by modelling RO operation. Any
Salt Passage (From RO Model) Reverse Osmosis         Genius   RO salt passage. Ratio of permeate TDS to feed TDS. Calculated by modelling RO operation. Any
Flux (From RO Model) Reverse Osmosis         Genius   PROPREITARY Any
Recovery (From RO Model) Reverse Osmosis         Genius   RO recovery. Ratio of permeate flowrate to feed flowrate. Drop rows where feed flowrate is null or zero. Calculated by modelling RO operation. Any
Cleaning Effectiveness Normalized Permeate Flowrate Reverse Osmosis % Intermittent normalized permeate flow after cleaning Analytics Brite Effectiveness of Cleaning on Permeate Flow PROPREITARY Any
Cleaning Effectiveness Normalized Pressure Drop Reverse Osmosis % Intermittent normalized permeate flow after cleaning Analytics Brite Effectiveness of Cleaning on Pressure Drop PROPREITARY Any
Cleaning Effectiveness Normalized Salt Passage Reverse Osmosis   Intermittent normalized permeate flow after cleaning Analytics Brite Effectiveness of Cleaning on Salt Passage PROPREITARY Any

 

 

 

 

 

 